| Product name: |
Digital Ultrasonic Flaw Detector |
| Product category: |
Ultrasonic Flaw Detector |
| Product type: |
AUD510 |
| Price: |
Contact us |
| Product brief introduction: |
|
|
Key Features
AUD 510 Ultrasonic Flaw Detector is designed for great inspection flexibility and for use in extreme environments. It combines a multitude of enhanced flaw detection and measurement features, a bright EL display, powerful data management, and numerous software features in a compact unit.
Functions
● Peak Hold: Automatically searching the peak wave inside the gate and hold it on the display.
● Equivalent diameter calculation: find out the peak echo and calculate its equivalent diameter.
● Continuous Record: Record the display continuously and save it to the memory inside the instrument.
● Defect Localization: Localize the defect position, including the distance, the depth and its plane projection distance.
● Defect Sizing: calculate the defect size
● Defect Evaluation: Evaluate the defect by echo envelope.
● DAC function: Distance Amplitude Correction
● AVG function: Distance Gain Size curve function
● Crack measure function: Measure and calculate the crack depth
● B-SCAN: Display the cross-section of the test block.
Real-Time Clock
Real time clock for tracking the time.
Communicaion
USB2.0 high-speed communication port
Range
0~ 9999mm (at steel velocity); range selectable in fixed steps or continuously variable.
Pulser
● Spike excitation with low, middle and high choices of the pulse energy.
● Pulse Repetition Rate: manually adjustable from 10 to 1000 Hz.
● Pulse width: Adjustable in a certain range to match different probes.
● Damping: 100Ω, 200Ω, 400Ω selectable to meet different resolution and sensitivity need.
● Probe work mode: Single element, dual element and through transmission;
Technical Specifications
● Range: (0 ~ 9999) mm
● Bandwidth: (0.5 ~ 15) MHz
● Material Velocity: (1000 ~ 9999) m / s
● Dynamic Range: ≥ 32dB
● Vertical linear error: ≤ 3%
● Horizontal linear error: ≤ 0.1%
● Resolution:> 40dB (5P14)
● Sensitivity Leavings: 60dB (flat-bottomed deep hole 200mmФ2)
● Rejection: (0 to 80)% Linear
● Noise level: ≤ 10%
● Power supply: DC 9V; lithium batteries work for 4 to 8 hours or more
● Ambient temperature: (-20 ~ 50) ℃
● Relative Humidity: (20 ~ 95)% RH
● Overall dimensions: 263 × 170 × 61 (mm)
Configuration
|
No. |
Item |
Quantity |
Standard Configuration |
1 |
Main body |
1 |
2 |
Straight Beam Probe |
1 |
3 |
Angle Probe |
1 |
4 |
Machine-probe Cable (Q9-Q9) |
1 |
5 |
Battery Module |
1 |
6 |
Power Adapter (Charger) |
1 |
7 |
Support Pillar |
1 |
8 |
Manual |
1 |
9 |
Instrument Case |
1 |
10 |
Datapro Software |
1 |
11 |
USB communication Cable |
1 |
|
| Back to Product page |
|
|